Christmas Sale Now On!
Order now to beat the January price increases and transform your bathroom for less!
Low Delivery Charges On All Orders UK Company Frequently Asked Questions

Stepping into a bathroom should be an experience of relaxation and rejuvenation, not a zap-fest of electrical surprises. But navigating the world of bathroom fixtures and their electrical requirements can feel like deciphering an ancient code. Enter the concept of electrical zones - your guardians against shocking mishaps and damp disasters in the wet zone.

Understanding UK Bathroom Electrical Zones is crucial for ensuring safety and compliance with regulations. These zones are defined in the IEE Wiring Regulations and are based on the area's proximity to water. They play a vital role in reducing the risk of electric shock that can occur when electricity and water mix. By defining specific zones, these regulations dictate where and how electrical appliances and fixtures can be installed in a bathroom.

 

So, what exactly are these zones?

Picture your bathroom as a series of concentric circles, like ripples emanating from a dropped pebble. Each circle represents a designated zone with its own set of electrical restrictions. Let's dive into the depths of each one:

Zone 0

Zone 0 is defined as the area inside the bath, basin, or shower - essentially, any space within a bathroom that can hold water​​. This zone is considered the most hazardous due to its direct contact with water. Therefore, electrical equipment installed here must be IPX7 rated, accommodating submersion, and the voltage should not exceed 12VAC or 30VDC. Importantly, only SELV (separated extra-low voltage) circuits are allowed, and any 230V transformer supporting this must be located outside the bathroom zones. Extra-low voltage cables are permitted within this zone and others​​.

Zone 1

Zone 1 covers the area above Zone 0, up to a height of 2.25m from the bottom of the bath or shower, and extends 1.2m horizontally from the centre of a shower outlet. In terms of width, this includes the full expanse of the bath, not just the seating area, meaning external bathtub handles should be considered when calculating this space. In this zone, any installed lighting should be on SELV or PELV (protective extra-low voltage) circuits, limited to 25VAC or 60VDC, and electric showers must comply with an IPX4 rating.

Zone 2

Zone 2 is the area beyond Zones 0 and 1, extending 0.6m horizontally and up to 2.25m vertically from these zones. Equipment in this zone should have an IPX4 rating. For shaver sockets, the standard is BSEN 61558-2, and they should be positioned where water spray is unlikely. Self-switches and sockets are allowed in this area, and any ceiling pull switch for a shower should be mounted above the 2.25-metre threshold, with only the operating chord present in Zone 2.


The 'Outside Zone'

The 'Outside Zone' refers to the rest of the room, including the area above the 'box'. This zone is broken down into two parts:

Part 1: Extends from where Zone 2 ends, up to three metres away from the outside edge of the bathtub. Towel rails or heaters supplied by 230V can be installed here but must be permanently wired into a flex outlet or similar, with all circuits 30mA, RCD protected​​.


Part 2: Encompasses the space more than three metres past the bathtub, the immediate area above the box, and the surrounding expanse at this height. Ceiling lights in this area do not need to be IP rated​​.

Showers and Wetrooms

The guidelines for showers follow similar patterns as for bathtubs, with Zone 0 being the foot basin space, Zone 1 the immediate area above this up to 2.25m in length, and Zone 2 registered from the outside edge of the foot basin. Wet rooms, however, have only two zones: Zone 0 is a projected line 100mm up from ground level, and Zone 1 extends up to the 2.25m upper level. There is no Zone 2 in wet rooms.

Underfloor Heating

In cases of underfloor heating, cables that pass through Zones 1 and 2 must be 30mA, RCD protected​​.

Best Practices and Regulations

Electricians must follow the specifications attached to each zone and understand corresponding measurements essential to safe installations. They should refer to Section 7 of the bs7671 18th edition for detailed guidance on installations in bathrooms. This guide includes instructions, advisory notes, and supplementary diagrams for various bathroom contexts.

Why Should You Care?

You may be pondering, "What's the significance of these zones? Is it not sufficient to simply install a standard light above my bath?" However, the implications of neglecting electrical zones are far from trivial. The combination of water and electricity is notoriously hazardous. Their unintended interaction can have severe repercussions, ranging from minor shocks to potentially fatal electrocution.

The existence of bathroom electrical zones is imperative for your safety and that of your family. They provide assurance that, even amidst water's erratic presence on your bathroom floor, your electrical fittings remain securely operational, silently fulfilling their purpose.

Implementing Your Understanding: An Instructional Approach

How, then, can you apply this essential knowledge to enhance the safety of your bathroom? Here are some actionable steps:

Seek professional advice: While having knowledge of the zones is beneficial, electrical installations should invariably be conducted by qualified professionals. An electrician can evaluate your bathroom's specific layout and suggest appropriate fixtures and installations for each zone.

Make informed choices: In selecting bathroom fixtures, it is crucial to consider their Ingress Protection (IP) ratings and voltage. Verify that they conform to the specifications required for their designated zone.

join us on facebook follow us on twitter

Stay Connected

Sign up for the latest offers, products and more!

...
Chat (Loading...)
Send us a message
Welcome:
Hi! Got a question or need advice? Send us a message, we'll reply right away. For stock checks, include the product reference number (just above the price).
Thank You

Your message has now been sent and we will get back to you as soon as possible.